Perma-Mark Home Page, www.perma-mark.com Perma-Mark Industries
17 River Street
Beverly, MA
USA      01915
Phone: (978) 236-1050
Fax: (978) 236-1075

PM-FLORO-18

Specifications
Ratio UL Specs MIL Specs
Withstands High Temps and Abrasion, Flexible 2 to 1 Ratio VW-1 150 C MIL DTL-23053/18, Class 1
Cross Reference Chart
3M/ECC Alpha Raychem Sumitomo
n/a n/a n/a K2
General Information
Description Usages Operating Temp Shrink Temp Packaging
Tough and abrasion resistant in mechanical environments. Has excellent properties for cut through and solvents. Recommended for applications where the properties of standard Kynar are desirable but with the added benefits of flexibility, greater clarity, reduced shrink temperature and long continuous lengths. -55 C to +175 C 150 C Spool
Physical Properties
Property (units) Test Method Requirements
Tensile Strength (psi) ASTM D638 3500 min
Elongation (%) ASTM D638 200 min
Specific gravity ASTM D792 2.0 max
Low temp. flex (-55 C) MIL-DTL-23053 No Cracking
Heat shock (275 C, 168 Hrs.) MIL-DTL-23053 No Cracking
Heat resistance (250 C, 168 Hrs.) ASTM D638 100 min
Secant modulus (psi) ASTM D882 100,000 min
Deformation (150 C, 1 hr) (%) UL 224 50 max
Longitudinal change (%) MIL-DTL-23053 +10, -10
Electrical Properties
Property (units) Test Method Requirements
Dielectric strength (volts/mil) ASTM D876 400 min
Volume resistivity (ohm-cm) ASTM D876 1.0 x 1011 min.
Chemical Properties
Property (units) Test Method Requirements
Copper Stability (180 C, 168 Hrs.) UL 224 70% of unaged value
Water absorption (%) ASTM D570 0.5 max
Fluid resistance (23 C, 24 Hrs.) Te MIL-DTL-23053 2000 min
Flammability UL 224 VW-1 Pass
Vacuum Outgassing TML%/ CVCM% ASTM E595 1.0 max/ 0.1 max
Measurement Chart Click here to view Measurement Information.